Table 132: Chassis Alarm Messages (continued)
Recommended ActionCLI MessageAlarm TypeComponent
Clean up the system file storage space
on the switch. For more information,
see Cleaning Up the System File Storage
Space.
RE RE number /var partition usage is
high
Minor (yellow)Routing Engine
Clean up the system file storage space
on the switch. For more information,
see Cleaning Up the System File Storage
Space.
RE RE number /var partition is fullMajor (red)
Use the request system configuration
rescue save command to set the
rescue configuration. For more
information, see Setting or Deleting the
Rescue Configuration.
Rescue configuration is not setMinor (yellow)
Install the required license for the
feature specified in the alarm. For
more information, see Software
Features That Require Licenses on the
QFX Series.
Feature usage requires a license
or
License for feature expired
Check whether a cable is connected
to the management Ethernet interface,
or whether the cable is defective.
Replace the cable, if required.
On models that have both em0 and
em1 management interfaces available,
you must connect both interfaces. If
both interfaces are not connected, the
alarm is raised. However, the alarm
has no service impact.
If you are unable to resolve the
problem, open a support case by using
the Case Manager link at
https://www.juniper.net/support/ or
call 1-888-314-5822 (tollfree, US or
1-408-745-9500 (from outside the
United States).
Management Ethernet 1 Link DownMajor (red)Management
Ethernet interface
628