Loading...
*** system operational: no
temperature temperature
slot type (10C - 70C) status
---- ------------------ ----------- -----------
0 LM-4 42 normal
0/1 GE-4 IOA 23 normal
6 SRP-100 32 normal
6 SFM-100 32 normal
6/0 SRP IOA 25 normal
7 SFM-100 30 normal
8 SFM-100 23 normal
9 SFM-100 25 normal
10 SFM-100 24 normal
13 LM-4 24 normal
13/0 GE-4 IOA 23 normal
fabric temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 70C
processor temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 70C
IOA temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 70C
Example 3Displays the environment on an E120 router
host1#show environment all
chassis: 11 slot (id 0x8, rev. 0x0)
fabric: 120 Gbps (rev. 1)
fans: fanSubsystemOk
nvs: ok (998MB flash disk, 14% full), matches running config
power: A ok, B not present
srp redundancy: mode is file-system-synchronization auto-sync
enabled, switch-on-error enabled
in sync
slots: ok
online: 1 2 6
standby: 7
empty: 0 3 5
fabric slots: ok
online: 6 7 8 9 10
line redundancy: none
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
fabric redundancy: ok
system operational: yes
Monitoring the System 341
Chapter 5: Managing the System

Table of Contents

Related product manuals