host1#show reboot-history
*** Entry 1 ***
time of reset: TUE APR 10 2001 20:25:59 UTC
run state: unknown
image type: diagnostics
location: slot (7)
build date: 0x3abf4337 MON MAR 26 2001 13:25:11 UTC
reset type: user reboot, task "scheduler", reason "not specified"
*** Entry 2 ***
time of reset: TUE APR 10 2001 20:25:44 UTC
run state: unknown
image type: diagnostics
location: slot (8)
build date: 0x3abf5d5f MON MAR 26 2001 15:16:47 UTC
reset type: user reboot, task "scheduler", reason "not specified"
*** Entry 3 ***
time of reset: TUE APR 10 2001 20:25:03 UTC
run state: unknown
image type: diagnostics
location: slot (4)
build date: 0x3abf3ee0 MON MAR 26 2001 13:06:40 UTC
reset type: user reboot, task "scheduler", reason "not specified"
See show reboot-history.
show running-configuration
Use to display the configuration currently running on the router, a specified
virtual router, a specified interface, or a specified category of router settings.
See full description and examples in show running-configuration on page 270.
See show running-configuration.
show version
Use to display the armed and running releases for every slot in the router and
the operational status of the SRP module and line modules for all E Series routers.
Use the all keyword with the E120 and E320 routers to display the operational
status of the IOAs.
Field descriptions
Model identification
CopyrightCopyright details for the system software
System ReleaseFilename, version, and date of the system software
currently running on the router
System running forHow long the router has been running (time elapsed
since the last boot of the router), date and time of last boot; does not reflect
the uptime of a particular SRP module
slotPhysical slot that contains the line module
stateStatus of the line module
348 Monitoring the System