host1#flash-disk compare all
WARNING: This command may take several minutes to complete.
Proceed? [confirm]
WARNING: No changes should be made to the system while this command is in
progress.
Please wait.........................................................
All file checksums matched.
Number of Files = 866
Number of Bytes = 61660650
■ Example 2—Shows output when one or more configuration files failed the
validation test
host1#flash-disk compare configuration
WARNING: This command may take several minutes to complete.
Proceed? [confirm]
WARNING: No changes should be made to the system while this command is in
progress.
Please wait......
At least one configuration file failed checksum test.
■ There is no no version.
■ See flash-disk compare.
synchronize
■ Use to force the NVS file system of the redundant SRP module to synchronize
with the NVS file system of the primary SRP module.
■ If you synchronize the redundant SRP module with the primary SRP module and
the redundant module is armed with a release different from the one it is currently
running, the redundant SRP module is automatically rebooted to load the armed
release.
■ Optionally, you can use the low-level-check keyword to force the router to
validate all files or only configuration files in NVS, and to synchronize all files
that failed the checksum validation test during the flash-disk-compare command
as well as any other files that are unsynchronized.
■ When you use the low-level-check keyword, you must also specify one of the
following keywords:
■ all—Validates all files in NVS, and synchronizes all files that failed the
checksum test as well as any other unsynchronized files; this option can
take several minutes to complete.
■ configuration—Validates all configuration files in NVS, and synchronizes all
files that failed the checksum test as well as any other unsynchronized files;
this option takes less time to complete because it validates only a subset of
the files in the NVS file system.
■ If one or more of the following conditions exist when you use the low-level-check
keyword, the command fails and the router displays a message that explains
why it cannot perform the synchronization:
■ The router does not contain a redundant SRP module.
386 ■ Managing Flash Cards on SRP Modules
JUNOSe 11.1.x System Basics Configuration Guide