2. Issue the show environment command to check which line modules are
configured to ignore diagnostics test failure.
host1#show environment
chassis: 14 slot (id 0x5, rev. 0x1)
fabric: 40 Gbps (rev. 0)
fans: fanSubsystemOk
nvs: ok (488MB flash disk, 43% full), matches running config
power: A ok, B not present
srp redundancy: mode is high-availability, state initializing
auto-sync enabled, switch-on-error enabled
sync in progress
slots: ok
online: 0 6 12
standby: 7
empty: 1 2 3 4 5 8 9 10 11 13
diagnostic failure is ignored on slot: 0
line redundancy: none
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
system operational: yes
3. Issue the no version of the command to return to the default setting for the slot:
host1(config)# no slot ignore-diagnostic-failure 12
4. Issue the show environment command to check that the slot no longer ignores
diagnostic test failures :
host1#show environment chassis: 14 slot (id 0x5, rev. 0x1)
fabric: 40 Gbps (rev. 0)
fans: fanSubsystemOk
nvs: ok (488MB flash disk, 43% full), matches running config
power: A ok, B not present
srp redundancy: mode is high-availability, state initializing
auto-sync enabled, switch-on-error enabled
sync in progress
slots: ok
online: 0 6 12
standby: 7
empty: 1 2 3 4 5 8 9 10 11 13
diagnostic failure is ignored on slot: 0,6,7
line redundancy: none
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
system operational: yes
If an SRP failure occurs when the router boots from the factory defaults or when
your configuration is lost, you can ignore test failures from the boot menu:
Ignoring Diagnostic Test Failures â–  407
Chapter 6: Managing Modules

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SYSTEM BASICS - CONFIGURATION GUIDE V 11.1.X and is the answer not in the manual?

Juniper SYSTEM BASICS - CONFIGURATION GUIDE V 11.1.X Specifications

General IconGeneral
BrandJuniper
ModelSYSTEM BASICS - CONFIGURATION GUIDE V 11.1.X
CategorySoftware
LanguageEnglish

Related product manuals