EasyManua.ls Logo

Juniper SYSTEM BASICS - CONFIGURATION GUIDE V 11.1.X

Juniper SYSTEM BASICS - CONFIGURATION GUIDE V 11.1.X
640 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Issue the show environment command to check which line modules are
configured to ignore diagnostics test failure.
host1#show environment
chassis: 14 slot (id 0x5, rev. 0x1)
fabric: 40 Gbps (rev. 0)
fans: fanSubsystemOk
nvs: ok (488MB flash disk, 43% full), matches running config
power: A ok, B not present
srp redundancy: mode is high-availability, state initializing
auto-sync enabled, switch-on-error enabled
sync in progress
slots: ok
online: 0 6 12
standby: 7
empty: 1 2 3 4 5 8 9 10 11 13
diagnostic failure is ignored on slot: 0
line redundancy: none
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
system operational: yes
3. Issue the no version of the command to return to the default setting for the slot:
host1(config)# no slot ignore-diagnostic-failure 12
4. Issue the show environment command to check that the slot no longer ignores
diagnostic test failures :
host1#show environment chassis: 14 slot (id 0x5, rev. 0x1)
fabric: 40 Gbps (rev. 0)
fans: fanSubsystemOk
nvs: ok (488MB flash disk, 43% full), matches running config
power: A ok, B not present
srp redundancy: mode is high-availability, state initializing
auto-sync enabled, switch-on-error enabled
sync in progress
slots: ok
online: 0 6 12
standby: 7
empty: 1 2 3 4 5 8 9 10 11 13
diagnostic failure is ignored on slot: 0,6,7
line redundancy: none
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
system operational: yes
If an SRP failure occurs when the router boots from the factory defaults or when
your configuration is lost, you can ignore test failures from the boot menu:
Ignoring Diagnostic Test Failures 407
Chapter 6: Managing Modules

Table of Contents

Related product manuals