A Appendixes
570 Keysight U8903B User’s Guide
Configuration 5
This configuration is similar to configuration 3, except that the DUT uses the U8903B
internal reference clock source as the reference clock.
Press on the FUNCTION panel to switch between audio generator or audio analyzer
mode, and press on the FUNCTION panel to switch to digital interface.
Figure A-8 DSI test configuration 5
1 Press Input Config > Connector, and select DSI as the digital analyzer input type.
2 At the digital generator, press DSI Config > Master Clock, and select On to turn on the
master clock.
3 Press DSI Config > W/Bclk Dir, and select Out as the word and bit clock direction.
U8903B
DUT
Pin 9
Pin 10
Pin 11
Pin 1
Bit clock
Frame Sync
Data
Master clock