EasyManuals Logo

Lucent Technologies 5ESS User Manual

Lucent Technologies 5ESS
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #456 background imageLoading...
Page #456 background image
............................................................................................................................................................
2
Check results and take appropriate action:
• If the result is
NG - INVALID PACKET GROUP, then examine the
associated office record 5219.
Refer to Translation Guide (TG-5), 235-080-100, for obtaining
office record numbers.
• For all others, refer to the Output Messages Manual,
235-600-750, for additional information.
............................................................................................................................................................
3
Stop. You have completed this procedure.
Procedure
............................................................................................................................................................
1
Initiate a manual heartbeat test on a specific association number:
TST:PATH,SCTPHB,ASSOC=c;
Where:
c = association number
Result:
Generates an SCTP heartbeat report for a specific association
number. If the result is other than
COMPLETED: TEST PASSED,
then CONTINUE with this procedure. Otherwise, EXIT this
procedure.
............................................................................................................................................................
2
Check results and take appropriate action:
• If the result is
NG - INVALID ASSOCIATION ID, then examine
the associated office record 5889.
Refer to Translation Guide (TG-5), 235-080-100, for obtaining
office record numbers.
• For all others, refer to the Output Messages Manual,
235-600-750, for additional information.
............................................................................................................................................................
3
Stop. You have completed this procedure.
Initiate SCTP Heartbeat
Maintenance Considerations
....................................................................................................................................................................................................................................
7-20
Lucent Technologies 235-200-118
Issue 3.02B, March 2007
E ND OF S TEPS
............................................................................................................................................................
E ND OF S TEPS
............................................................................................................................................................

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies 5ESS and is the answer not in the manual?

Lucent Technologies 5ESS Specifications

General IconGeneral
BrandLucent Technologies
Model5ESS
CategorySwitch
LanguageEnglish

Related product manuals