115
GSM
Status message
Indicates the provider of the inserted SIM card and the signal strength.
Reporting the status of SIM card
This option must be set to for the SMS delivery via SIM card, as it is otherwise
impossible.
Report GSM signal loss
This option activates or deactivates the notification in case of GSM signal loss.
GPRS
If you use a SIM card, you can insert the GPRS information of your provider in order to
receive alarms from your alarm panel via the GPRS connection of the SIM card in case
of a power failure or internet connection error. These information are different for each
provider / mobile plan. Please ask you provider about the correct information.
APN
The APN (Acess Point Name) is similar to the gateway settings of your local area
network and is your internet gateway via the GPRS network.
User
Enter the username for your APN. In some cases, it can be blank.
Password
Enter the password for your APN. In some cases, it can be blank.
MMS
MMS messaging is not supported and can be ignored.
SMS
SMS keyword
It is required to specify an SMS keyword to send commands to the alarm panel by
text message. In addition, you need to enter a previously specified and activated
PIN code (“Home” “PIN codes”).
In our example, the SMS keyword is test, the PIN code is by default 1234.
The following table lists the possible commands. Please do not use blank spaces
in the text messages!
Action
Command
Sample text message
Description
Change
status of
alarm
panel
MODE
MODE:test,1234,1,4
Use the command to arm or disarm the alarm panel or
to set one of the home modes.
First value (1) Area number 1
Second value (4) Home mode 3
0: Disarm
1: Full Arm
2: Home Arm 1
3: Home Arm 2
4: Home Arm 3
Request
image
REQIMG
REQIMG:test,1234,1,10
Use this command to take a picture with one of the
connected PIR cameras.
First value (1) Area number 1
Second value (10) PIR camera zone 10

Table of Contents