Smoke detector V2
Product description:
The smoke detector V2 works according to optical principles. In a measurement chamber,
the concentration of smoke particles is measured. If the concentration exceeds a set limit,
the smoke detector will sound an alarm of 85dB (measured from a distance of 1 meter /
3.2 feet). The smoke detector V2 connects to the XT alarm panel and, in case of a smoke
alarm, the siren(s) of the alarm panel will also sound an alarm. Additionally, the alarm
panel can notify you via telephone call, SMS, E-Mail, push notification, and contact a
security service centre (some functions not available for all XT alarm panels).
Sensor data:
Dimensions (without mount) Ø 10.6 x 4.4 cm (4.17 x 1.73 inches)
Weight: 220 Gramm (0.48 pounds)
Place of installation: Only indoors
Working environment: -10°C to +45°C (14F to 113F)
Humidity: Maximal 95% (non-condensing)
Radio frequency: 868.35 MHz
Conforms to the following standards: DIN EN 54-7 and EN 14604
Detection method: Optical
Internal siren: 95 dB / 1 meter (3.2 feet)
1. LED / learn button:
After inserting the batteries, the smoke detector V2 automatically enters a
calibration phase. During this time, the LED flashes and the smoke detector V2
can be connected to the alarm panel.
If the batteries run low, the LED flashes every 30 seconds.
When the smoke detector transmits a signal to the alarm panel, the LED lights
up.
Press the learn button in the following cases:
To connect the smoke detector V2 with the alarm panel
To perform a range test
To perform a function test
2. Batteries