256
5. Battery compartment
The radiator valve thermostat requires two 1.5 V AA alkaline batteries.
Other functions:
Anti-frost:
If the radiator valve thermostat detects the risk of frost, the valve opens automatically
and causes the temperature to rise.
Anti-calcification:
To prevent calcification, the valve opens and closes once a week Saturday night at 11
p.m. The display shows “CAL” during this process.
Installation of radiator valve thermostat V2
The radiator valve thermostat replaces the temperature control of the heater. To install
the thermostat, please proceed according to the following steps:
1. Unscrew the existing temperature control from the heater.
2. Check that the valve can be pressed in. Lubricate the valve in any case. Install the
fastening screw thread onto the heater valve and fasten it by rotating it clockwise. Do
not apply excessive force. The radiator valve thermostat is sufficiently fastened if it
does not rotate by itself anymore.
3. Insert the batteries in the radiator valve thermostat. The display shows “InS.” As long
as flashes, the motor works.
4. Open the web interface of the alarm panel, go to the menu “Sensors” “Add”, and
press “Start”.
5. In the first three minutes after the batteries were inserted, you need to press the
Boost/Learn button of the radiator valve thermostat for ten seconds.
6. The display of the radiator valve thermostat shows “888” briefly.
7. Press to add the radiator valve thermostat to the alarm panel.
8. You can now “stop” the learn mode of the alarm panel or continue to add additional
sensors.
9. You can set-up the thermostat via or do it later on.
10. If you press the day/night control key of the radiator valve thermostat afterwards,
it is calibrated and the display shows “AdA” during the process.
11. When the radiator valve thermostat finished the calibration process, it goes into
manual mode and the setpoint temperature is set to the standard value of 18.5 °C.