EasyManua.ls Logo

Lupus Electronics XT 1 Plus - Top-Hat Rail Relay Installation

Lupus Electronics XT 1 Plus
332 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
304
Top-hat rail relay
Attention:
This product is not compatible with the XT1 or XT2 without “Upgrade dongle to XT2
Plus.”
Product description:
Top-hat rail relays can be installed in control cabinets in only a few steps and allow you
to control connected end devices remotely (web interface/ smartphone) or by hand. You
can also set up automation rules, e.g. when the top-hat rail relay is to be activated or
deactivated automatically. For further information, refer to the chapter “Automation.”
Technical data:
Dimensions
DIN2: 90.2 x 36.30 x 57.5 mm (3.55 x 1.42 x 2.26
inches) (W x H x D)
DIN3: 90.2 x 53.00 x 57.5 mm ( 3.55 x 2.08 x 2.26
inches) (W x H x D)
Weight
DIN2 0.085 kg (0.18 lbs)
DIN3 0.131 kg (0.288 lbs)
Tampering protection
No
Status displayed
Yes, red LED in front
Status monitoring and indication
by alarm panel
Yes
Radio frequency
2.4 GHz ZigBee HA 1.2
Radio performance
Max. 10 mW
Transmission range
Approx. 30 to 100 meters (32 to 109 yards)
depending on the local conditions)
Modulation
FM (SRD category 2)
Possible load
DIN2 max. 3680 W 16 A
DIN3 max. 6900 W 30 A
Load type
Resistive load
Power consumption in standby
mode
0.6 W
Relay
Closing contact, single-pole, µ contact
Switching cycle
40000 (DIN2 16 A and DIN3 30 A, resistive load)
Duty cycle
< 1 % pro h
Operating mode
S1
Switch type
Independently mounted switch
Protection type
IP20
Protection class
I
Mode of action
Type 1
Impulse withstand voltage
2500 V
Degree of pollution
2
Power supply
230 V / 50 Hz
Compliant with regulations
CE, FCC, RoHs
Operating temperature and max.
humidity
-10 to 45°C (14F to 113F), max. 85% (not
condensing)

Table of Contents