and press “Start”.
5. Press the Learn button of the heat detector. The menu should list the heat detector
after a short while. Press to complete the connection process
Range test:
1. Open the alarm panel menu “Sensors” “Range” and press “Start.”
2. Press the Learn button of the heat detector.
3. The sensor and the signal strength should be indicated. The higher the indicated
number the better the reception (1-9).
Please note:
If the signal strength at the place of installation is below 4, we advice to use a wireless
repeater, since it is normal that the signal strength may fluctuate for 2-3 points, thus,
a signal loss is possible.
Please note:
If the heat detector triggers an alarm, the alarm panel, as well as, the heat detector
will sound this alarm irrespective of the mode of the alarm panel (disarm, arm,
home).
Even if the connection to the alarm panel is interrupted (e.g. radio interference, too
far away from the alarm panel), the internal siren of the heat detector sounds an
alarm.