Supervision:
The outdoor siren V2 sends a supervisor signal every 30 to 50 minutes. If the signal is
not received by the alarm panel, the web interface shows the status “Out of order.”
Alarm simulation
1. You can test the siren’s function by simulating an alarm or triggering the
tampering contact.
2. Warning: The siren is very loud (107 dB). Deactivate the sound either by
disarming the alarm panel or by removing the batteries.
Alarm memory:
If an alarm was triggered, the outdoor siren V2 sounds a (trumpet) signal when disarming
to make you aware of the alarm. This signal cannot be deactivated!
Duration of the audio alarm:
The audio alarm of the outdoor siren V2 is set to a duration of three minutes. If the alarm
panel interrupts the alarm before the duration ended, the outdoor siren will stop as well.
Reset:
You can delete the memory and configuration of the outdoor siren V2 in the following way:
Remove the power supply (remove batteries / unplug mains adapter).
Press and hold the learn button.
Reestablish the power supply
Keep the learn button pressed for approx. 5 seconds
o The siren will emit a sound and the LEDs will flash one after the other.
Menu “Alarm system” “Siren settings” “Sirens”
This menu consists of two parts. The upper part allows you to transmit settings to all
connected indoor and outdoor sirens. The lower part lists your connected sirens and
allows you to enter the sensor edit menu of the sirens.