alarm panel.
6. Keep the Learn button (1) pressed for approx. ten seconds; the LED lights up
briefly. Release the Learn button. The relay transmits the connection request and
the LED flashes twice.
7. As soon as the alarm panel has received the connection request, the sensor list
shows the sensor. Add the relay to the sensor list by pressing .
Range test:
1. Open the alarm panel menu “Sensors” “Range” and press “Start”.
2. Press the learn button.
3. The sensor and the signal strength should be indicated. The higher the indicated
number the better the reception (1-9).
Please note:
If the signal strength at the place of installation is below 4, we advise to use a ZigBee
repeater, since it is normal that the signal strength may fluctuate for 2-3 points, thus,
a signal loss is possible.
External switch:
Attention: The external switch connector uses 115V!
You can use an external switch for easier operation.
Any operation of the connected switch changes the state of the relay.
You cannot use a push button instead of a switch.
Note:
The relay only switches the phase conductor. The neutral conductor is always
closed.
The relay can be activated and deactivated manually on the website.
You can save dynamic or scheduled programming in the Automation menu.
After a power failure, the relay returns to the last state before the power failure.
The relay is not compatible with the wireless repeater and cannot be saved in the
backup file.
The signal of the relay with power meter V2 can be enhanced by a ZigBee
repeater”