297
three times and two signals sound, indicating the successful integration of a tag in
the tag reader.
4. If you want to add several tags, hold them one after the other (at intervals of 5
seconds) in front of the tag reader or restart the entire process.
5. Exit the installation mode of the tag reader by setting SW1 back to OFF.
Range test:
1. Open the alarm panel menu “Sensors” “Range” and press “Start”.
2. Press the arm or disarm button and afterwards set the SW1 to “ON”.
3. Press the disarm button.
4. The sensor and the signal strength should be indicated. The higher the indicated
number the better the reception (1-9).
5. Switch the SW1 back to “OFF”.
Please note:
If the signal strength at the place of installation is below 4, we advise to use a repeater,
since it is normal that the signal strength may fluctuate for 2-3 points, thus, a signal
loss is possible.
How to use the tag reader V2:
After having completed the tag reader installation as described above, you can use the
tag reader as follows:
1. Arming/disarming
Press the Arm or Disarm button once to activate the tag reader.
2. You have five seconds to hold a tag in front of the tag reader. If the tag is
recognized within this time, the alarm panel is armed or disarmed.
Caution:
If there are system errors in the alarm panel when the system is armed, repeat the arming
process within 10 seconds, since otherwise the alarm panel remains disarmed!
Alternatively, you can activate the menu force “arming with failure” in the web interface of
your alarm panel.
Restoring the factory default:
1. Open the housing. Remove the batteries, and then press any button to discharge
any residual voltage.
2. Set switch 2 to ON, reinsert the batteries. The tag reader signals the reset
(including the deletion of the added tags) with an audio signal followed by two more
signals. The Status LED starts flashing. Set switch 2 to OFF again and close the
housing.
3. Delete the tag reader from the sensor list of the alarm panel.
Please note:
Tags can only be deleted by resetting the tag reader to the factory default.
It is impossible to delete individual tags from the configuration of the tag reader.
You can add up to 30 tags to the tag reader V2.
Individual tags can be added to an unlimited amount of tag readers.