89
Restart device to schedule
Use this function to schedule the regular restart of the alarm panel. After enabling
this option, it takes 24 hours until it is performed for the first time. Hence, it is not
possible to test a “restart in 5 minutes” with this option.
Please note: After a restart, the alarm panel has no information about the sensors
and all sensors (even open door contacts) are listed with “N/A”. If a sensor changes
its status from “N/A” to “open” (because it was open before the restart), an alarm
is triggered if this sensor should normally trigger an alarm in the current mode of
the alarm panel.
Energy saving mode during power interruption
Specify the time after which the alarm panel is to enter the energy saving mode in
case of power failure. It ends immediately in case of alarm.
Reporting of radio transmission failures
Enable this function if the alarm panel is to report radio interferences (e.g. by e-
mail, text message, contact ID, etc.) in case they are longer than the selected
duration (one or two minutes). No acoustic alarm is triggered.
Notify on wrong PIN
If this option is enabled, the alarm panel will notify you via Push message and e-
mail if a wrong PIN code was used. It is required that these messaging methods
are available.
Automatic status report to the central station
Specify the intervals at which the alarm panel is to report the status to the security
firm. Thus, the security firm recognises that the alarm panel is online. It is
necessary to set Contact ID to “all events” (recommended setting) or to “status
events” (alarms are not transmitted not recommended). If you select “alarm
events”, status events, including this status report, are not transmitted to the alarm
service station.
Waiting period after switching
Specify how long the alarm panel has to wait until it sends the first status report to
the security firm after it was started.
Notify on missing Ethernet connection
Specify whether you want to hear a regular audio warning in case the network
connection is interrupted (or no Ethernet cable is connected). If this function is
disabled, the error LED does not signal a missing Ethernet connection.
Notification of a home automation rule execution
If this function is enabled, you receive a message by contact ID, e-mail, text
message, telephone, or push notification when an automation rule is executed.
Additionally, it is required that the condition “Automation rule” in the respective
notification drop-down menu (as condition / filter) is activated.
Protect PIN code
If this function is enabled, the keypad will be locked and will not react to any inputs
for 15 minutes after an incorrect PIN code was entered five times!
Automatic HTTPS redirection
By default, this option is enabled to ensure that only the SSL encrypted connection
(port 443) to the alarm panel is used. If you disable this option, against which we
strictly advise, you can also use the unencrypted port 80.
Autologout
By default, this option is enabled. After you have been inactive in the webinterface,
the alarm panel logs you out automatically.