99
Setting for area
Set for which of the two areas you want to adjust the settings.
Doorbell
Set the volume of the doorbell.
During the entry delay time (Arm mode)
Set the volume for the entry delay while the alarm panel is in arm mode.
During the exit delay time (Arm mode)
Set the volume for the exit delay when you activate the arm mode.
During the entry delay time (Home mode)
Set the volume for the entry delay while the alarm panel is in home mode.
During the exit delay time (Home mode)
Set the volume for the exit delay when you activate the home mode.
Bell
Set the volume of the warning sound of the alarm panel in case of an error (see
chapter “System” “Status” “Panel”). External sirens do not sound this
warning sound.
Confirmation beep of the alarm panel
Allows you to set the last confirmation sound of the internal siren of the alarm
panel.
Caution chime at the end of the delay time
Set for how many seconds of the entry delay time you want to be notified before
the delay time ends.
Example:
If you enter 5 seconds, a warning sound (countdown) will start to sound only for
the last 5 seconds before the entry delay ends. If you activate Continuous, the
warning sound will sound for the entire duration of the entry delay.
Siren delay
If this setting is enabled, the internal and external sirens will sound the alarm
delayed (burglar alarm follow or instant). The delay does not affect smoke alarm,
water alarm, entrance delay, etc..
Alarm while disarmed
This option is “On” by default. If this setting is active, the internal siren of the alarm
panel, as well as, all connected sirens sound an acoustic alarm even if the alarm
panel is disarmed. This includes every alarm that is not silent, e.g. panic alarm or
24h smoke alarm. You can see which sensors are set to 24h via “Sensors” “List”
“Alarm overview.” If you only want to be informed about an alarm while the alarm
panel is disarmed by e-mail, text message, contact ID, but not in an acoustic way,
set the option to “Off.”
Alarm duration
This option refers to the alarm duration of all connected sirens. You can specify
the maximum alarm duration. If the alarm panel is disarmed again, the acoustic
alarm is switched off.
Note:
If the alarm duration of an external siren is set shorter with the DIP switches
(SW3+4, if available), as described in the according siren’s manual, then, the
audio alarm of the external siren will end early. Vice versa, the alarm duration of
an external siren will end early if the alarm duration in the alarm panel is set for a
shorter period than the DIP switches (SW3+4). If the alarm duration is “disabled,”
all added sirens remain off.