692 Matrix PRASAR UCS System Manual
•Go to Call Progress Tones.
Change the values of the CPT-related Timers as desired.
Click Submit.
How to use
It is important that users of PRASAR UCS also get acquainted with the different Call Progress Tones played by the
system, so that they understand the meaning of the terms used for various tones. Therefore, PRASAR UCS makes
it possible for users to listen to the various Call Progress Tones.
CPTG Region Codes
Region Type Tones FREQ CADENCE (ms)
Region 1
ON OFF ON OFF ON OFF
Ring Back Tone 350+440 400 200 400 2000
Busy Tone 440 750 750
Error Tone 440 250 250
Confirmation Tone 350+440 100 100
Feature Tone 350+440 100 900
ICWT 440 100 2900
CCWT 440 100 100 100 2700
Dial Tone 1 440 Continuous
Dial Tone 2 350+440 Continuous