Mercury 305 CID - Battery Gauge; Testing

Mercury 305 CID
967 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTRUMENTATION - 4D-390-823225--1 1096
5. Connect jumper wire from terminal G (GND) to
terminal S (SEND).
72748
Typical
6. Turn ignition switch to RUN.
7. Indicator needle of gauge being tested must read
at position B. If not, replace gauge.
72749
Position B
Typical
Battery Gauge
TESTING
1. Remove cables from battery and fully charge bat-
tery.
2. Connect negative (–) jumper lead from battery to
gauge terminal G (GND).
3. Connect positive (+) jumper lead from battery to
gauge terminal I or +12 V.
72750
Typical
4. Check gauge reading; if not as shown replace
gauge.
72751
Typical