INSTRUMENTATION - 4D-1790-823225--1 1096
INSTALLATION
1. Apply Loctite Pipe Sealant with Teflon to threads
of transmission fluid temperature switch.
2. Install switch with sealing washer in transmission
and tighten securely.
NOTE: Switch is mounted in a fitting on transmission
cooler on some later models.
3. Reconnect harness wires and coat with Liquid
Neoprene.
72770
c
a
b
a - Transmission (Typical)
b - Transmission Fluid Temperature Switch With Sealing
Washer
c - Harness Wires
4. Check transmission fluid level.