5C-26 - ROCHESTER 4 BARREL CARBURETOR 90-823225--1 1096
4. Install nine attaching screws. Tighten securely in
sequence as numbered.
72111
a - Long
b - Short
c - Countersunk
1
2
3
4
5
6
78
9
b
c
a
b
b
b
c
IMPORTANT: Hanger size may vary from specifi-
cation chart. Manufacturer varies hanger size to
make up differences in carburetor castings. Al-
ways install the same size hanger as was re-
moved from the carburetor. Difference in hang-
ers is the hole location, which affects secondary
fuel metering.
72139
a - Hole Location Changes Fuel Metering
b - Richer
c - Leaner
b
c
a
5. Install secondary metering rods into hanger with
upper ends toward each other as shown.
72140
a - Hanger
b - Metering Rods
b
a
b
6. Install metering rods and hanger and secure with
screw. Tighten securely.
72110
a - Screw
b - Metering Rods
c - Hanger
a
b
c