CLOSED COOLING MODELS - 6B-2990-823225--1 1096
a. All Models:
(1) Install Quicksilver Flushing Attachment
(or equivalent) over water intake open-
ings in gear housing.
(2) Connect hose between flushing attach-
ment and water tap.
72672
b
a
a - Quicksilver Flushing Attachment
b - Garden Hose
b. Models Equipped with Belt Driven Seawa-
ter Pickup Pump: In addition to supplying
water to the drive (as previously outlined for
“All Models”), perform the following.
!
CAUTION
If cooling system is to be flushed with boat in the
water, seacock (if so equipped) must be closed,
or water inlet hose must be disconnected and
plugged to prevent water from flowing into boat.
(1) Close seacock (if so equipped) or discon-
nect and plug seawater inlet hose.
(2) Loosen hose clamp and remove seawa-
ter inlet hose at location shown. Connect
an additional tap water hose to inlet fitting
using an appropriate adaptor.
72532
b
a
a - Seawater Pickup Pump
b - Seawater Inlet Hose
2. Partially open water tap (approximately 1/2 maxi-
mum capacity) and allow drive unit and cooling
system to fill completely. Do not use full tap water
pressure.
NOTE: Drive unit is full when water is discharged out
of drive unit, and/or seawater section of closed
cooled system is full when water is discharged
through propeller.
3. Place remote control lever in NEUTRAL position
and start the engine. Operate engine at idle
speed in NEUTRAL gear for 10 minutes or until
discharge water is clear, then stop engine.
4. Shut off tap water. Remove hose and flushing at-
tachment from drive unit. On belt driven seawater
pickup pump models, also remove hose and
flushing attachment from pump inlet.
5. Follow instructions “a” or “b.”
!
CAUTION
If boat is in the water, seacock (if so equipped)
must remain closed until engine is to be re-
started, to prevent contaminated water from
flowing back into cooling system. If boat is not
fitted with a seacock, water inlet hose must re-
main disconnected and plugged, to prevent wa-
ter from flowing into cooling system and/or boat.
As a precautionary measure, attach a tag to the
ignition switch or steering wheel with the warn-
ing that the seacock must be opened or the water
inlet hose reconnected prior to starting the en-
gine.