Operation and Maintenance
618
< Description>
(1) Name of the system and firmware version
System name : Name of the system is displayed. N/A is displayed when there is no
name.
Firmware version : Management firmware version.
(2) System Health: Status of system
Name : Name of the system is displayed. N/A is displayed when there is no
name.
Power : DC power status is displayed.
Display Value Description
Off DC power of all Servers is OFF
On DC power of at least one Server is ON
Health : Failure status is displayed. This indicates the worst status among all the
Servers, including the spare server.
Display Value Description
Normal No failure occurred, or only Correctable Error
occurred.
Non-Critical Recoverable Error occurred. Maintenance of the
system is required.
Critical Fatal error occurred. Maintenance of the system
is required.
(3) Server Health: Status of server
ID : [0] indicates Server 1 (including MGM1). [1] indicates Server 2 (including
MGM2).
Name : Name of the server is displayed. N/A is displayed when there is no
name.
PowerServer : DC power status of Server
Display Value Description
Off DC power of the relevant Server is OFF.
On DC power of the relevant Server is ON.
Health : Failure status is displayed. This indicates the status of the relevant
server.
Display Value Description
Normal No failure occurred, or only Correctable Error
occurred.
Non-Critical Recoverable Error occurred. Maintenance of the
Server is required.
Critical Fatal Error occurred. Maintenance of the Server
is required.
Status : Operating status of the server
Display Value Description
Stopped Server stopped (DC OFF)
BIST Running BIST Running status
Initializing Booting up (loading) status