Program 12 to 15
Xen Topaz Programming Manual 94
PROGRAM 15: EXTENSION BASIC SETUP
15-07: P
ROGRAMMING FUNCTION KEYS
Description
Use Program 15-07 : Programmable Function Keys to set the functions of an extension’s Programmable
Function Key.
For certain functions, you can append data to the key’s basic function. For example, the function 26 ap-
pended by data 1 makes a Group Call Pickup key for Pickup Group 1. You can also program Function Keys
using Service codes.
In order to clear any previously programmed key, press the CLEAR key to erase any displayed code.
Input Data
Default
IN
SA
SB COPY
Extension Number Max. 4 digits
Line Key Number Function Number Additional data
01-46
(KTS with DLS)
0-99 : Normal Function Number
*00-*99 : Appearance Function Number
Refer to the Function code List
Key Number Function Number Additional Data
KY01 *01(Trunk Line Key) 1
KY02 *01(Trunk Line Key) 2
: : :
KY12 *01(Trunk Line Key) 12
KY13 00 (No Setting) 0
: : :
KY21 00 (No Setting) 0
KY22 *05(Hybrid Operation Key)
(Loop Key)
2
KY23 00 (No Setting) 0
: : :
KY46 00 (No Setting) 0