Xen Topaz Programming Manual 17
Program 10 to 11
PROGRAM 10: SYSTEM CONFIGURATION SETUP
10-03: PCB SETUP
Conditions
None
Feature Cross Reference
None
Prog. No. Item Input data Default
10-03-01
ISDN Line Mode 0 : No setting
1 : T-Point
2 : S-Point
3 - 5 : Not Used
6 : S-Point (Leased Line)
1
10-03-02
Logical Port Number (see Note 1)
[0 : No setting] : 0
[1 : T-Point] : 1 - 8
[2 : S-Point, 6 : S-Point (Leased Line)] :
11-26
0
10-03-03
Connection Type 0 : P-MP
1 : P-P
0
10-03-04
Layer 3 Timer Type (see Note 2)
1-5 1
10-03-05
CLIP Information Announcement 0 : Disable
1 : Enable
1
10-03-06
Connection Bus Mode (S-point
only)
0 : Extended Passive Bus
1 : Short Passive Bus
1
10-03-07 S-point DID digits 0-4
0
10-03-08
Dial Sending Mode 0 : Enblock sending
1 : Overlap sending
1
10-03-09
Dial Information Element
(Only for Overlap Sending Mode)
0 : Keypad Facility
1 : Called Party Number
1
10-03-10 -Not Used-
- -
10-03-11 -Not Used-
- -
10-03-12 -Not Used-
- -
10-03-13 -Not Used-
- -
10-03-14 Service Protocol for S-point
0 : Keypad facility
1 : Special Protocol for Topaz system
0