PROGRAM 26: ARS SERVICE & LEAST COST ROUTING
26-02: D
IAL ANALYSIS TABLE FOR ARS
Description
Use Program 26-02 : Dial Analysis Table for ARS to set pre-transaction tables for selecting Automatic
Route Selection (ARS).
Service Type 1 (Route to Trunk Group Number) - the number routes to a trunk group.
Service Type 2 (F-Route Selected) - The number is controlled by the F-Route table.
Input Data
Conditions
None
Feature Cross Reference
Automatic Route Selection
IN
SA
SB
Dial Analysis Table Number
1-200
Prog. No. Item Input Data
Default
Related
Program
26-02-01 Dial
Max. 16 digits ( 0-9,*,#,@) @ = Wildcard
No set-
ting
26-02-02
Service Type 0 : No ARS
1 : Route to Trunk Group
2 : Select F-Route access
0
26-02-03
Service Number
In Service Type 1:
Select Trunk Group Number (0-25, 0=no route)
In Service Type 2:
F-Route Time Schedule Not Used = 0-500 (F-
Route Table Number).
Refer to Program 44-05.
F-Route Time Schedule Used = 0-500
(F-Route Selection Number).
Refer to Program 44-04.
0
44-04
44-05
26-02-04
ARS Class of
Service
0-16 0
26-02-05
Dial Treatment
0-15 0
26-02-06
LCR Carrier Ta-
ble
0-25 0

Table of Contents