Program 40 to 92
Xen Topaz Programming Manual 313
PROGRAM 90: MAINTENANCE PROGRAM
90-06: T
RUNK CONTROL
Description
Use Program 90-06 : Trunk Control is used for the trunk maintenance. Busy Out lets you block a PCB
from placing outgoing calls. Once busied out, none of the ports on the PCB can be used for new calls. Ex-
isting calls, however, are not torn down.
Input Data
Conditions
None
Feature Cross Reference
None
Telephone Programming Instructions
To enter data for Program 90-06 (Trunk Control):
1. Enter the programming mode.
2. Enter 90 05
3. Enter the number of the item you want to program.
4. Select the Menu number to be programmed by pressing the FLASH or the VOLUME▲ or VOLUME▼
keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you’ve exited that series’ programming section.
IN
SA
SB
Trunk Port Number
1-51
Menu Number
1 : Set Busy Out
2 : Reset/Release Busy Out
90-06-01 Trunk1
Menu
90-06-xx Trunkx
xxxxx