Program 16 to 20
Xen Topaz Programming Manual 144
PROGRAM 20: SYSTEM OPTION SETUP
20-18: S
ERVICE TONE TIMERS
Description
Use Program 20-18 : Service Tone Timer to set the values for the system service tone timers.
Refer to the following chart for a description of each option, its range and default setting.
Input Data
Conditions
None
Feature Cross Reference
♦ Distinctive Ringing, Tones, and Flash Patterns
IN
SA
SB
Prog.
No.
Item Input data Default Description
Related
Program
20-18-01
Extension Dial
Tone sending
Timer
0 - 64800
(sec.)
30 After getting Intercom dial tone,
a KTS user has this interval to
dial the first digit of the Inter-
com call.
20-18-02
Busy Tone send-
ing Timer
0 - 64800
(sec.)
15
20-18-03
Congestion Tone
sending Timer
0-64800(sec.) 10 A Busy Tone when system re-
sources run short. (such as
DTMF receiver resources)
20-18-04
Warning Tone
sending Timer
0-64800(sec.) 10 This option sets the interval
between Call Waiting tones.
This timer also sets the interval
between Off Hook Signalling
alerts.
20-18-05
KTS Confirma-
tion Tone send-
ing Timer
0-64800(sec.) 10
20-18-06
Interval of Call
Waiting Tone
0-64800(sec.) 10
20-18-07
Intrusion Tone 0-64800(sec.) 0 After a call is interrupted (such
as Barge In, Voice Mail
Conversation Recording, Voice
Over, etc), the system repeats
the Intrusion Tone after this
interval. Normally, you should
enter 0 to disable this interval.
20-18-08
Conference tone
Interval
0-64800(sec.) 0
20-18-09
Warning Beep
Tone Signalling
Interval
0-64800(sec.) 60 14-01-18