Program 16 to 20
Xen Topaz Programming Manual 138
PROGRAM 20: SYSTEM OPTION SETUP
20-15: R
ING CYCLE SETUP
Description
Use Program 20-15 : Ring Cycle Setup to define the ringing cycles for each ring type.
Input Data
Ring Cycle
Conditions
None
IN
SA
SB
Prog.
No.
Incoming Ring Type Ring Cycle No. Default
Related
Program
20-15-01 Normal Incoming Call on Trunk
1-13
3
20-15-02 PBX,CES incoming Call
8
20-15-03 Internal Incoming Call
8
20-15-04 DID/DISA
8
20-15-05 DID
8
20-15-06 -Not Used-
8
20-15-07 Doorphone ringing for SLT
2
20-15-08 Virtual Extension Ring
8
20-15-09 Call-back
4
20-15-10 Alarm for SLT
5
20-15-11 VRS Waiting Message Incoming
Call
6
Ring Cycle No. Ring Cycle
1
Not Supported
2
On:2.0 / Off:4.0
3
On:1.0 / Off:2.0
4
On:0.5 / Off:0.5
5
On:0.3 / Off:0.3
6
On:0.5 / Off:0.5 / On:0.5 / Off:1.5
7
On:0.4 / Off:0.2 / On:0.4 / Off:2
8
On:0.3 / Off:0.3 / On:0.3 / Off:2.1
9
On:0.2 / Off:0.2 / On:0.2 / Off:0.2 / On:0.2 / Off:2.0
10
On:1.0 / Off:4.0
11
On:0.3 / Off:0.3 / On:0.3 / Off:4.1
12
On:1.0 / Off:3.0
13
On:0.3 / Off:0.3 / On:0.3 / Off:2.1