Program 21 to 25
Xen Topaz Programming Manual 201
PROGRAM 24: HOLD/TRANSFER SETUP
24-05: D
EPARTMENT GROUP TRANSFER TARGET SETUP
Description
Use Program 24-05 : Department Group Transfer Target Setup to assign the Abbreviated Dialling bin
which is used as the destination of the extension for the Department Group.
Input Data
Conditions
None
Feature Cross Reference
Transfer
Telephone Programming Instructions
To enter data for Program 24-05(Department Group Transfer Target Setup):
1. Enter the programming mode.
2. Enter 24 05
3. Enter the number of the item you want to program.
4. Select extension Group number to be programmed by pressing the FLASH or the VOLUME or
VOLUME keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you’ve exited that series’ programming section.
IN
SA
SB
Department Group Number
1-32
Day/Night
Mode
Abbreviated
Dial Area
Number
Default Description
Related
Program
1-8
0-1999 1999
The Abbreviated Dialling area is used as
the registration place for the destination of
the transferred telephone number at the
time of the extension group transfer use.
11-11-27
13-04
24-04
24-05-01 Ex Gr1
Mode1 ABB =1999
24-05-xx Ex.Grxx
xxxxx