Program 21 to 25
Xen Topaz Programming Manual 163
PROGRAM 21: OUTGOING CALL SETUP
21-08: R
EPEAT DIAL SETUP
Description
Use Program 21-08 : Repeat Dial Setup to define the automatic Repeat Dial data.
Input Data
Conditions
None
Feature Cross Reference
♦ Repeat Dial
Telephone Programming Instructions
To enter data for Program 21-08 (Repeat Dial Setup):
1. Enter the programming mode.
2. Enter 21 08
3. Enter the number of the item you want to program.
4. Enter data for the item you selected + HOLD.
5. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you’ve exited that series’ programming section.
IN
SA
SB
Prog. No. Item
Input Data Default
Related
Program
21-08-01
Repeat Redial Count
Set how many times a Repeat Redial will automati-
cally
repeat if the call does not go through.
0-255
3
21-08-02
Repeat Redial Interval Time
This timer sets the interval between Repeat Redial
attempts.
0-64800
(sec.)
60
21-08-03
Repeat Dial Calling Timer
After dialling the trunk call, Repeat Redial main-
tains the
call after this interval. After this interval, the system
terminates the call, waits the Repeat Redial Time
(Timer 02) and tries again.
0-64800
(sec.)
30
21-08-04
Time for Send Busy Tone for ISDN Trunk
Set the timer (sec) to send out Busy Tone with an
ISDN
line, when called party is in busy.
0-64800
(sec.)
0
21-08-01
Repeat Times 3
21-08-xx
xxxxx