Program 21 to 25
Xen Topaz Programming Manual 217
PROGRAM 25: DID/DISA SETUP
25-11: DISA T
OLL RESTRICTION CLASS
Description
For systems that use Toll Restriction, use Program 25-11 : DISA Toll Restriction Class to assign a Toll
Restriction Class (1-15) to each DISA user (1-15). The system uses the Toll Restriction Class you enter in
Program 21-05 and 21-06. The Toll Restriction Class assigned to a DISA call is based on the DISA Class of
Service and user, which is determined by the password the caller dials.
When programming, you make a separate entry for each Night Service mode.
Input Data
Conditions
You cannot use Program 21-05 to assign Toll Restriction to DISA trunks.
Feature Cross Reference
Direct Inward System Access (DISA)
Toll Restriction
Telephone Programming Instructions
To enter data for Program 25-11 (DISA Toll Restriction Class):
1. Enter the programming mode.
2. Enter 25 11
3. Enter the number of the item you want to program.
4. Select Trunk port number to be programmed by pressing the FLASH or the VOLUME▲ or VOLUME▼
keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you’ve exited that series’ programming section.
IN
SA
SB
DISA User Number
1-15
Day/Night Mode Toll Restriction Class Default
1-8 1-15 2
25-11-01DISA-U1
Mode1 T/RClass2
25-11-xxDISA-Uxx
xxxxx