PROGRAM 90: MAINTENANCE PROGRAM
90-10: S
YSTEM ALARM SETUP
Description
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You can designate an
alarm as Major or Minor. This program also assigns whether or not the alarm is displayed to a key tele-
phone and whether or not the alarm information is reported to the pre-defined destination.
Input Data
Default
IN
SA
SB
Alarm Number 001-100
Alarm Type Report Note Is Used To Advise of... Action
1 2(MIN) 0 Board Initializa-
tion Error
Initialization Failure or the
PCB is defective
Remove and reinstall the
PCB.
2 2(MIN) 0 Board Installation
Error
PCB was unplugged with-
out using the proper pro-
cedure.
Check the PCB installa-
tion.
3 2(MIN) 0 Communication
Error between
Board and EXIFU
PCB communication fail-
ure has occurred.
Remove and reinstall the
PCB. If RECover mes-
sage is received in the
alarm report, the PCB is
good. If not, replace with
a new PCB.
4 2(MIN) 0 PCB Program
Download Error
Download may have
failed because the PCB is
blocked (disabled) or the
sub -program does not
exist on the system flash
card.
After unblocking the PCB,
if RECover message is
received in the alarm re-
port, it is corrected. If not,
then replace the system
flash card.
5 0 0 -Not Used- - -
6 0 0 Blocking (No de-
fault setting)
Failure may have oc-
curred because:
• Terminal blocking
detected.
• Terminal is unplugged.
• Wire is disconnected.
• 308 card is defective.
Check the terminal wiring
and reconnect properly.
Then unplug and plug in
the PCB. If RECover
message is received in
the alarm report, it is cor-
rect. If not, replace the
PCB and/or
terminal.
7 1(MAJ) 0 -Not Used- - -
8 1(MAJ) 0 RAM Backup
Battery Error
RAM backup battery on
the
308M PCB is un-
plugged or
defective.
Check the battery con-
nector. If it is connected
correctly, then replace the
battery.
9 0 0 -Not Used- - -