Xen Topaz Programming Manual 4
Introduction to Programming
Before you Start Programming
How to Enter the Programming Mode
Depending on the mode of programming, the system may allow more than one person in the pro-
gramming mode at one time. With telephone programming, two people can program simultane-
ously. Using the PC Program, only one person is allowed in programming. If the same program
number is being defined simultaneously, the last changes made to the program will be accepted.
To enter the programming mode:
1. Go to any working display telephone.
In a newly installed system, use extension 200 (port 1).
2. Do not lift the handset.
3. Press SPK.
4. 6321
5. Dial the system password + HOLD.
Refer to the following table for the default system passwords. To change the passwords, use
Program 90-02.
It is NOT recommended to change these data unnecessarily. The worst case
may happen is that there is no normal way to go into program mode again, if
the digits entered is forgotten, then.
How to Exit the Programming Mode
To exit the programming mode:
When you are done programming, you must be out of a program’s options to exit (pressing the DC
key will exit the program’s option).
1. Press DC key to exit the program’s options, if needed.
2. Press SPK. You see, "SavingSystemData" if changes to were to the system’s programming.
3. The display shows "CompleteDataSave" when completed and will exit the phone to an idle mode.
To save a customers database, a blank Compact Flash Memory Card is required. Insert the
card into the EXIFU-A1 and, using Program 90-03, save the software to the Compact Flash
Memory Card. (Program 90-04 is used to reload the customer data if necessary.) Note that a
Compact Flash Memory Card can only hold one customer database. Each database to be
saved will require its own separate card.
Alternatively, use the PCPro Programming application to download the system data through the LAN or
RS-232 port of the EXFU-A1/B1 and save it to your PC’s disk drive. This same application can be used to
restore the saved database if required.
Password Level Program at this Level
12345678 2(IN) All programs in this Manual not listed below for SA and SB
0000 3(SA)
10-01,10-02,10-24,12-02,12-03,12-04,15-01,15-07,15-09,15-
10,15-11,
20-16,21-07,21-14,22-04,22-11,25-08,30-03,32-02,40-02,45-
02,45-03,
90-03, 90-04,90-06,90-07,90-19