Program 40 to 92
Xen Topaz Programming Manual 298
PROGRAM 80: BASIC HARDWARE SETUP FOR SYSTEM
80-03: DTMF T
ONE RECEIVER SETUP
Description
Use Program 80-03 : DTMF Tone Receiver Setup to define the various levels and timers for the DTMF
Tone Receiver.
Input Data
MF
SA
SB
DTMF Tone Receiver Type Number
1 : DTMF Receiver for Extension
2 : DTMF Receiver for Trunk
3,4,5 : -Reserve-
Prog. No. Item Input Data
Related
Program
80-03-01 Detect Level
0 : 0dBm…....-25dBm
1 : - 5dBm……-30dBm
2 : -10dBm……-35dBm
3 : -15dBm……-40dBm
4 : -20dBm……-45dBm
5 : -25dBm……-50dBm
6 : -30dBm……-55dBm
80-03-02 Start delay time 0-255 (0.25ms – 64ms)
80-03-03 Min. detect level
0-15
detect level 0 : –10dBm(0) to –25dBm(15)
detect level 1 : –15dBm(0) to –30dBm(15)
detect level 2 : –20dBm(0) to –35dBm(15)
detect level 3 : –25dBm(0) to –40dBm(15)
detect level 4 : –30dBm(0) to –45dBm(15)
detect level 5 : –35dBm(0) to –50dBm(15)
detect level 6 : –40dBm(0) to –55dBm(15)
80-03-04 Max. detect level
0-15
detect level 0 : 0dBm(0) to –15dBm(15)
detect level 1 : – 5dBm(0) to –20dBm(15)
detect level 2 : –10dBm(0) to –25dBm(15)
detect level 3 : –15dBm(0) to –30dBm(15)
detect level 4 : –20dBm(0) to –35dBm(15)
detect level 5 : –25dBm(0) to –40dBm(15)
detect level 6 : –30dBm(0) to –45dBm(15)
80-03-05 Forward twist level
0-9 (1dB…10dB)
80-03-06 Backward twist level
0-9 (1dB…10dB)
80-03-07 ON detect time
1-255 (15+ 15ms…3825ms)
80-03-08 OFF detect time