Program 12 to 15
Xen Topaz Programming Manual 59
PROGRAM 12: NIGHT SERVICE MODE SETUP
12-04: H
OLIDAY NIGHT SERVICE SWITCHING
Description
Use Program 12-04 : Holiday Night Service Switching to define a yearly schedule of holiday night-switch
settings. This schedule is used for setting of special days which the company is expected to be closed,
such as national holiday.
Input Data
Default
All Night group are no Holiday settings.
Conditions
None
Feature Cross Reference
♦ Night Service
Telephone Programming Instructions
To enter data for Program 12-04 (Holiday Night service Switching):
1. Enter the programming mode.
2. Enter 12 04
3. Enter the number of the item you want to program.
4. Select the Night Mode Service Group number to be programmed by pressing the FLASH or the
VOLUME▲ or VOLUME▼ keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you’ve exited that series’ programming section.
IN
SA
SB
Night Mode Service Group Number 1-4
Days and Months Time Pattern Number
0101-1231
(Ex. 0101 = Jan.1
st
, 1231 = Dec.31
st
)
0-10
(0 : No Setting)
12-04-01ModeGrp1
Date01/01 Pttrn0
12-04-xx
xxxxx