Xen Topaz Programming Manual 16
Program 10 to 11
PROGRAM 10: SYSTEM CONFIGURATION SETUP
10-03: PCB SETUP
Note 1) The Relays can be assigned up to 2 ports for a 2PGDU Unit.
For BRIU Unit
Note 1) The start port number of a BRI line is displayed. Two logic ports are automatically assigned to a
BRI line.
Note 2) Each timer value of Layer3 are set up for every type of Program 81-06 (Trunk mode) and Program
82-06 (S-Bus).
Prog.
No.
Item Input data Default
10-03-01
Terminal Type
Physical port Number 1-2
0 : No setting
8 : Doorphone
(1-7,10,11 : -Not Used-)
Physical port Number 3-4
0 : No setting
6 : External Speaker
7 : External Trunk Audible
9 : External Music Source (MOH or
BGM)
(1-5,8,10,11 : -Not Used-)
Physical port 1-2: 8
Physical port 3-4 : 6
10-03-02
Logical Port Number 0-6
0
10-03-03
Relay setting (see
Note 1)
0-4
(0 : Not Used)
Relay No.1 : 1
Relay No.2 : 2
ISDN Line Number 1-4
IN
SA
SB