Xen Topaz Programming Manual 15
Program 10 to 11
PROGRAM 10: SYSTEM CONFIGURATION SETUP
10-03: PCB SETUP
Description
Use Program 10-03 : PCB Setup to setup and confirm the Basic Configuration data for each PCB.
When changing a defined terminal type, first set the type to ‘0’ and then plug the new device in to have the
system automatically define it, alternatively redefine the type manually.
Program 10-03 allows the editing of installed units (PCB’s), you can not edit the settings if the slot is un-
used, install the PCB first then edit the settings.
Note: The items highlighted in grey are read only and cannot be changed.
Input Data
For 308M/308E/008E Unit
Note 1) Reference and a setup are possible only for a Station port.
For 2PGDU Unit
Slot Number 1-18
Physical Port Number
Extension : 1-8
Trunk : 9-11
Prog. No. Item Input data Default
10-03-01
Terminal Type 0 : No setting
1 : Multi-Line Telephone
2 : Single Line Telephone
10 : DSS Console
13 : Trunk
3-9,11,12 : -Not Used-
0
10-03-02
Logical Port Number (see Note
1)
Station : 0-72
Trunk 0-51
0
10-03-03 Transmit Gain Level for SLT 1-63(-15.5…….+15.5dB) 32
(0dB)
10-03-04 Receive Gain Level for SLT 1-63(-15.5…….+15.5dB) 32
(0dB)
Related
Programming
33-01
Physical Port Number 1-4
IN
SA
SB