Program 16 to 20
Xen Topaz Programming Manual 109
PROGRAM 16: DEPARTMENT GROUP
16-01: E
XTENSION (DEPARTMENT GROUP BASIC DATA SETUP)
Description
Use Program 16-01 : Department Group Basic Data Setup to set the function mode for each department
group.
Input Data
IN
SA
SB COPY
Extension (Department) Group Number 1-32
Prog. No. Item Input data Default
Related
Program
16-01-01
Department Name
Max. 12 Character No setting 11-07
16-01-02
Department Calling Cycle
Use this option to set the call routing
for Department Calling.
Routing can be either circular (cycles
to all phones in group) or priority
(cycles to highest priority extensions
first).
0 : Priority Routing
1 : Circular Routing
0 16-02
16-01-03
Department Routing When Busy
Use this option to set how the system
routes an Intercom call to a
busy Department Group member.
Intercom callers to the extension can
either hear busy or route to the first
available department number. This
only occurs for calls to the extension
directly, not the department number.
0 : Normal (Intercom caller
to busy department member
hears busy)
1 : Circular (Intercom callers
to busy department member
routes to idle member)
0
16-01-04
Hunting Mode 0 : A last extension is called
and hunting is stopped.
1 : Circular
0
16-01-05
STG All Ring Mode Operation 0 : Manual
1: Automatic
0 11-16-10
16-01-06
STG Withdraw mode 0 : Disable (Camp On)
1 : Enable (Overflow Mode)
0
16-01-07
Call Recall Restriction for STG 0 : Disable (Recall)
1 : Enable (non-Recall)
0
16-01-08
Maximum queuing number of STG
Call
0-32 (0 : No queuing)
0
16-01-09
Department Group Call no Answer
Time
Set how long a call will ring a Depart-
ment group extension before
hunting occurs.
0-64800(sec.)
15
16-01-10
Hunt type
Set the type of hunting
for each Extension
(Department) Group:
0 : No queuing
1 : Hunting When Busy
2 : Hunting When No
Answer
3 : Hunting When Busy or
No Answer
0