Program 21 to 25
Xen Topaz Programming Manual 160
PROGRAM 21: OUTGOING CALL SETUP
21-06: T
OLL RESTRICTION TABLE DATA SETUP
Input Data (Cont)
Conditions
None
Feature Cross Reference
Toll Restriction
IN
SA
SB
Prog. No. Item Table Input Data Default Description
21-06-08
PBX Access
Code
1-4 Dial (Up to
2 digits)
No setting Use this option to enter the PBX
Access Code. When the system
is behind a PBX, this is the code
users dial to access a PBX trunk.
Toll Restriction begins after the
PBX access code. For PBX
trunks (Program 14-04) the sys-
tem only Toll Restricts calls that
contain the access code. Always
program this option when the sys-
tem is behind a PBX, even if you
don’t want to use Toll Restriction.
PBX Access Codes can be up to
2 digits, using 0-9, #, * and LINE
KEY 1 (don’t care). When using
Account Codes, do not use an
asterisk within a PBX access
code. Otherwise, after the *, the
trunk would stop sending digits to
the central office. Entries 1-4 cor-
respond to the 4 PBX Access
Codes. Each code can have up to
2 digits.
21-06-09
Specific dial out-
going code
1-20
Dial (Up to
8 digits)
No setting
21-06-10
Outgoing Call
Code Setup
1-20
Dial (Up to
4 digits)
No setting