Loading...
Program 21 to 25
Xen Topaz Programming Manual 165
PROGRAM 21: OUTGOING CALL SETUP
21-10: D
IAL BLOCK RESTRICTION CLASS PER EXTENSION
Description
Use Program 21-10 : Dial Block Restriction Class Per Extensions to define the Toll Restriction Class to
each extension when the extension is set for Dial Block Restriction. If this data is “0”, Toll Restriction Class
follows Program 21-09-01.
Input Data
Conditions
None
Feature Cross Reference
Toll Restriction
Telephone Programming Instructions
To enter data for Program 21-10 (Dial Block Restriction Class Per Extensions):
1. Enter the programming mode.
2. Enter 21 10
3. Enter the number of the item you want to program.
4. Select the Extension number to be programmed by pressing the FLASH or the VOLUME or
VOLUME keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you’ve exited that series’ programming section.
IN
SA
SB
Extension Number
Max. 4 digits
Toll Restriction Class Default
0,1-15(0 : No setting) 0
21-10-01 TEL200
T/R Class 1

Table of Contents