Program 40 to 92
Xen Topaz Programming Manual 291
PROGRAM 80: BASIC HARDWARE SETUP FOR SYSTEM
80-01: S
ERVICE TONE SETUP
Description
Use Program 80-01 : Service Tone Setup to define up to 64 Service Tones. Each service tone is defined
by the combination of 32 Basic Tones.
Input Data
*Basic Tone
IN
SA
SB
Service Tone Number
01-64
Prog. No. Item Input Data
Related
Program
80-01-01 Repeat Count 0-255 (0 : Endless)
Unit Number
1-8
Prog. No. Item Input Data
Related
Program
80-01-02 Basic Tone Number* 0-33 (0 : No Tone, 33: Default Time Slot)
80-01-03 Duration Count 1-255 (100-25500ms)
80-01-04 Gain level(dB) 1-63 (-15.5…..+15.5dB)
Basic Tone
Number
Frequency
(Hz)
Level(dB)
Basic Tone
Number
Frequency
(Hz)
Level(dB)
1 420 -13 17 520/650 -13/-19
2 520 -13 18 650/780 -13/-19
3 580 -13 19 780/1040 -13/-19
4 660 -13 20 1040 -13
5 700 -13 21 -Reserve- -
6 800 -13 22 -Reserve- -
7 880 -13 23 -Reserve- -
8 1050 -13 24 -Reserve- -
9 430 -13 25 -Reserve- -
10 440/480 -13/-13 26 -Reserve- -
11 480/620 -13/-13 27 -Reserve- -
12 440 -16 28 -Reserve- -
13 -Reserve- - 29 -Reserve- -
14 520/650 -19/-13 30 -Reserve- -
15 650/780 -19/-13 31 -Reserve- -
16 780/1040 -19/-13 32 -Reserve- -