Program 40 to 92
Xen Topaz Programming Manual 320
PROGRAM 90: MAINTENANCE PROGRAM
90-11: S
YSTEM ALARM REPORT SETUP
Description
Use Program 90-11 : System Alarm Report to define the details of the system alarm report.
Input Data
Conditions
None
Feature Cross Reference
None
IN
SA
SB
Prog. No. Item Input Data Default
90-11-01
System Alarm Display Telephone
Assign the display KTS port that should re-
ceive system alarms.
Up to 4 digits No setting
90-11-02
Report Method
0- No report
1- Auto-Call (by E-mail) to
outside
0
90-11-03
-Not Used- - -
90-11-04
-Not Used- - -
90-11-05
-Not Used- - -
90-11-06 SMTP Host Name Up to 255 characters
No setting
90-11-07 SMTP Host Port Number 0-65535
25
90-11-08 To Address Up to 255 characters
No setting
90-11-09 Reply Address Up to 255 characters
No setting
90-11-10 From Address Up to 255 characters
No setting
90-11-11 DNS Primary Address 0.0.0.0-255.255.255.255
0.0.0.0
90-11-12 DNS Secondary Address 0.0.0.0-255.255.255.255
0.0.0.0
90-11-13 Customer Name Up to 255 characters
No setting