Program 12 to 15
Xen Topaz Programming Manual 54
PROGRAM 12: NIGHT MODE
12-02: A
UTOMATIC NIGHT SERVICE PATTERNS
Description
Use Program 12-02 : Automatic Night Service Patterns to define the daily pattern of the auto night
switch setting. Each Night Mode Group has 10 patterns. These patterns are used in Programs 12-03 and
12-04. The daily pattern consists of 20 timer settings.
Input Data
Example 1: Time Pattern 1
0:00 9:00 12:00 13:00 17:00 18:00 22:00 0:00
To make the above schedule, it is necessary to set the data as follows:
Time Setting 01 : 00:00 – 09:00 Mode 3 (Midnight)
Time Setting 02 : 09:00 – 12:00 Mode 1 (Day)
Time Setting 03 : 12:00 – 13:00 Mode 4 (Rest)
Time Setting 04 : 13:00 – 17:00 Mode 1 (Day)
Time Setting 05 : 17:00 – 18:00 Mode 4 (Rest)
Time Setting 06 : 18:00 – 22:00 Mode 2 (Night)
Time Setting 07 : 22:00 – 00:00 Mode 3 (Midnight)
Example 2: Time Pattern 2
0:00 0:00
To make the above schedule, it is necessary to set the data as follows:
Time Setting 01 : 00:00 – 00:00 Mode 2 (Night)
Night Mode Service Group Number 1-4
Time Pattern Number 01-10
Set Time Number 01-20
Start Time End Time Operation Mode
0000-2359 0000-2359 1-8
Mode3
Midnight
Mode1
Day
Mode4
Rest
Mode1
Day
Mode4
Rest
Mode2
Night
Mode3
Midnight
Mode2
Night
IN
SA
SB