16-34
16-9. Weld commands(MIG、TIG-FORCE application)
16-9-1. ARC-SET_TIGFC
Format
ARC-SET_TIGFC Ib=[Base Amp] Ip=[Peak Amp] WFb=[Base WFS] WFp=[Peak WFS]
FRQ=[Frequency] S=[Speed]
Function It specifies welding conditions for TIG Force. Base Amp Base amperage: [1-999] A
Condition Using TIG-FORCE. Peak Amp Peak amperage: [1-999] A
Lock condition Arc lock (Internal execution) Base WFS Min. wire speed: [0.10-30.00] m/min
Syntax check None. Peak WFS Max. wire speed: [0.10-30.00] m/min
Frequency Frequency: [0.0-500.0] Hz
Speed Welding speed: [0.01-120.00] m/min
Example Perform TIG welding with base amp at 120A, peak amp. At 180A, base wire feed speed at 1 m/min, peak
wire feed speed at 12 m/min and frequency at 0.5 Hz at the speed of 0.5 m/min.
ARC-SET_TIGFC Ib=120 Ip=180 WFb=1 WFp=12 FRQ=0.5 S=0.50
16-9-2. CRATER_TIGFC
Format
CRATER_TIGFC Ib=[Base Amp] Ip=[Peak Amp] WFb=[Base WFS] WFp=[Peak WFS]
FRQ=[Frequency] T=[Time]
Function It specifies crater conditions for TIG Force. Base Amp Base amperage: [1-999] A
Condition Using TIG-FORCE. Peak Amp Peak amperage: [1-999] A
Lock condition Arc lock (Internal execution) Base WFS Min. wire speed: [0.10-30.00] m/min
Syntax check None. Peak WFS Max. wire speed: [0.10-30.00] m/min
Frequency Frequency: [0.0-500.0] Hz
Time Crater time: [0.00-99.99] s
Example Perform crater welding with base amp at 120A, peak amp. At 180A, base wire feed speed at 12 m/min,
peak wire feed speed at 1 m/min and frequency at 0.5 Hz for 0.2 second.
ARC-SET_TIGFC Ib=120 Ip=180 WFb=1 WFp=12 FRQ=0.5 S=0.50
16-9-3. LOAD TIGFC
Format
LOAD TIGFC
Function It loads the temporarily stored welding conditions
for TIG Force.
Condition Using TIG-FORCE.
Lock condition Arc lock (Internal execution)
Syntax check None.
Example
LOAD TIGFC
16-9-4. SAVE TIGFC
Format
SAVE TIGFC
Function It temporarily stores welding conditions for TIG
Force in buffer.
Condition Using TIG-FORCE.
Lock condition Arc lock (Internal execution)
Syntax check None.
Example
SAVE TIGFC