16-21
16-5-28. P-HOTTM
Format
P-HOTTM [Value]
Function It adjusts pulse hot time. Value
Adjustment value [−10 - +10]
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Adjust the pulse hot time to +1.
P-HOTTM +1
The same command in
conventional models
16-5-29. PMODE
Format
PMODE [Mode]
Function It sets pulse mode. Mode
Condition Weld package.
Pulse mode
[SOFT/HARD/HYBRID].
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Change pulse mode to “SOFT”.
PMODE SOFT
The same command in
conventional models
PMODE
16-5-30. PPEAK
Format
PPEAK [Value]
Function It adjusts pulse peak time. Value
Adjustment value [−50 - +50]
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example
Adjust the pulse peak time to +1.
PPEAK+1
The same command in
conventional models
16-5-31. PRISE
Format
PRISE [Adjustment value]
Function It adjusts the pulse rise angle. Value
Condition Weld package.
Lock condition Arc lock (Internal execution).
Syntax check None.
Panasonic fully digital welding
power sources: [-50 - +50]
Other power sources: [-5 - +5]
Example Adjust the pulse rise angle set value by +2.
PFALL +2
16-5-32. STICKCHK
Format
STICKCHK [ON/OFF]
Function It starts or terminates the stick check operation. ON/OFF ON: to start the stick check.
Condition Weld package. OFF: to terminate the stick check.
Lock condition Arc lock.
Syntax check None.
Example Do stick check.
STICKCHK ON
The same command in
conventional models
OUTB OPORT#211=*