15-20
15-4-3. Powder control
Powder
control
[Powder]: Feeding powder, (Yes), or no powder, (No).
[Delay of motor on]: Time delay for feed motor start, (0.0 - 5.0)s
[Delay of main arc off]: Time delay for main power off,
(0.0-5.0)s
[Output for powder warning]: Warning signal output terminal for
lower powder level.
15-4-4. Pulse/Slope control
Pulse
slope
[Pulse]: With pulse, (Yes), or without pulse, (No).
[Frequency]: Frequency range
[Pulse duty]: Pulse width setting, (15 - 85)%
[Upslope]: Upslope time, (0.0 - 5.0)s
[Down slope]: Down slope time, (0.0 - 5.0)s
15-4-5. Gas control
Gas
control
[PG preflow]: Pre-flow time for Plasma gas, (5 - 25)s
[PG postflow]: Post-flow time for Plasma gas(10 - 30)s
[SG preflow]: Pre-flow time for Shield gas, (0.0 - 5.0)s
[SG postflow]: Post-flow time for Shield0 gas, (0 - 20)s
15-4-6. Inching speed
Inching
speed
[High]: High powder feed speed, (0 - 100)(%)
[Low]: Low powder feed speed, (0 - 100)(%)
15-4-7. Pilot arc
Pilot arc
[Output port]: Automatically set by welding machine.
[Output for Pilot]: ON terminal during generating pilot arc.
[Pilot arc・・・]: At emergency stop error generation, the pilot
arc is discontinued, (Yes), or continued, (NO).