16-32
16-8-10. PLASMAGAS
Format
PLASMAGAS [ON/OFF]
Function It turns on or off the plasma gas. ON/OFF Plasma gas control
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Turn on the plasma gas.
PLASMAGAS ON
The same command in
conventional models
16-8-11. POWDFED
Format
POWDFED = [Feed rate]
Function It sets the powder feed rate.
Condition
Feed rate Powder federate (Motor speed)
[0, 14 – 100]
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Set the powder feed rate to 20.
POWDFED 20
The same command in
conventional models
16-8-12. PWDMOTOR
Format
PWDMOTOR [ON/OFF]
Function It turns on or off the powder feed motor power. ON/OFF Powder feed motor control
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Turn on the powder feed motor
PWDMOTOR ON
The same command in
conventional models
16-8-13. PWDSLP
Format
PWDSLP Ib= [Base amp] Ip= [Peak amp] [Slope range] [Value]
Base amp End base amperage of the slope
[5 – 200] A
Function It sets a slope control condition for powder
plasma welding application.
Peak amp End peak amperage of the slope
[5 – 200
] A
Condition
Lock condition Arc lock (Internal execution).
Slope range Slope range
T=: Time designation
D=: Distance designation
NEXT: By the next point.
Syntax check None.
Example Change the base amperage to 25A and the peak
amperage to 100A for 10seconds.
PWDSLP Ib=25 Ip=100 T=10.00
Value T=: Time [0.01 - 999.99] s
D=: Distance [0.01 - 999.99] mm
NEXT: Nothing