16-23
16-5-38. WFED
Format
WFED [Feed rate]
Function It sets wire feed rate. Feed rate
Condition Weld package
Wire feed rate.
[0.00 - 15.00] m/min
Lock condition Arc lock (Internal execution)
Syntax check None
Example Set wire feed rate to 10 m/min.
WFED 10.00
The same command in
conventional models
WFED
16-5-39. WIREFWD
Format
WIREFWD [ON/OFF]
Function It starts or terminates wire forward
feed.
ON/OFF ON: to feed wire.
OFF: to terminate wire feed.
Condition Weld package *
Lock condition Arc lock
Syntax check None
Prior to this command, it is necessary to
insert the “AMP=” command that specifies
wire speed.
Example Feeds wire forward.
WIREFWD ON
The same command in
conventional models
OUTB OPORT#212=*
16-5-40. WIRERWD
Format
WIRERWD [ON/OFF]
Function It starts or terminates wire retraction. ON/OFF ON: to start wire retraction.
Condition Weld package OFF: to terminate wire retraction.
Lock condition Arc lock *
Syntax check None
Prior to this command, it is necessary to
insert the “AMP=” command that specifies
wire speed.
Example Retracts wire
WIRERWD ON
The same command in
conventional models
OUTB OPORT#213=*
DELAY 0.1
OUTB OPORT#212=*
16-5-41. WIRSLDN
Format
WIRSLDN [Value]
Value Fine adjustment value which will
be added to the system set value.
[-125 - +125]
Function It adjusts the wire slow-down speed.
Increase the value to shorten the time to
generate an arc.
Decrease it for better arc start.
*
Condition Weld package
Executing +1 adjustment twice
does not result in +2.
Lock condition Arc lock (Internal execution)
Syntax check None
Example Adjust the system set value by +1.
WIRSLDN +1
The same command in
conventional models
WIRESLDN