16-8-5. IB_POWD
Format
IB_POWD = [Value]
Function It sets base amperage for powder plasma
welding application.
Value Base amperage [5 – 200] A
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Set the base amperage to 20A.
IB_POWD 20
The same command in
conventional models
16-8-6. IP_POWD
Format
IP_POWD = [Value]
Function It sets the peak amperage for powder plasma
welding application.
Value Peak amperage [5 – 200] A
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Set the peak amperage to 95A.
IP_POWD 95
The same command in
conventional models
16-8-7. PDUTY_POWD
Format
PDUTY_POWD = [Value]
Function It sets the pulse width. Value Pulse width [15 – 85]
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Set the pulse width to 50.
PDUTY_POWD 50
The same command in
conventional models
16-8-8. PFRQ_POWD
Format
PFRQ_POWD = [Pulse frequency]
Function It sets pulse frequency. Frequency Pulse frequency [0.5 - 25.0]
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Set the pulse frequency to 6.0.
PFRQ_POWD 6.0
The same command in
conventional models
16-8-9. PLARC
Format
PLARC [ON/OFF]
Function It turns on or off the pilot arc. ON/OFF Pilot arc control
Condition
Lock condition Arc lock (Internal execution).
Syntax check None.
Example Turn on the pilot arc.
PLARC ON